Suzanne asked ... Washing programme stops after 3 minutes?    |    Rif asked ... Kenwood Dishwasher KID60S20 leaking from front?    |    Fraser asked ... Spares for power craft ppcs 38cc?    |    FB asked ... Toyota Yaris Speed Camera Warning Beep?    |    Ela asked ... Worcester 30 Cadillac combi boiler won’t fire up and the EA?    |    Click here to ask your question

vokera combi hot water issue?

Hi
My hot water tap has to be on full flow in order to trigger the boiler to fire up. Can it be adjusted to fire up on a slower flow or is there a sensor/switch that needs replacing? the ch side is perfect and the dhw does get to a good temp.
Steve, October 2012
Thanks for the reply, this is what i've done so far. On the three way manifold I've removed both plungers that activate the micro switches as they were a bit stiff, so cleaned them up so they now operate smoothly & replaced the diaphragm. the microswitch that opereates first when dhw is demanded seems a little stiff in its operation so I'll replace that too. Do you know where the outlet filter is situated? Once cleaned and if the fault still exists whats next to look at in your opinion? Just a reminder of whats what, its a Vokera maxim 24e that will only fire up the boiler (when hot water needed as ch is ok) when the tap for dhw is on or very near to full blast.
Regards

Steve, October 2012
Change water flow switch ,or hot water out let filter is blocked

ltd, October 2012
link Click here to see other fixes for Vokera.