GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

Scantronic 9000 alarm?

I have old scantronic 9000 series alarm in metal box which has tamper fault following a shock sensor replacement. Still cannot reset it,we opened box and checked wires but light lit red on electronic board,can you help me reset please ??
Trev, October 2012
Yep start linking or replace splitter :)

e manno, October 2012
try to link each tamper zone out on the splitter with a bit of wire,see how you get on ,do it one at a time

gts, October 2012
i know its not the best solution e manno,but it seems the only one at the moment

gts, October 2012
find the main tamper on the pc board,link it out with a bit of wire till you get the new splitter atleast you will have ur alarm working again

gts, October 2012
Trev don't throw the towel in just yet,

You can replace the splitter yourself, take a look here,

www.actmeters.com/440-Tamper-Splitter

Me give you little advice mate, chances are engineer won't have splitter on van, he do some meter checks and remove splitter and wire tampers into global,

The splitter is there not just to identify which lines the tamper is on, it's probably fitted for a very good reason, it could cause falsies if removed.

It's an easy swap, mains off, disconnect battery,remove and refit one wire at a time.

e manno, October 2012
no joy guys, looks like i have to call someone in,all your advice and guidance upto press has been appreciated, thanks.

Trev, October 2012
What's the numbers on the splitter? We tell you if there's any reset pins on it, the relay sounds as if it's stuck open, would of thought depowering it would of reset the relay though.

We try our best to help you Trev but it sounds like you need a new splitter.

e manno, October 2012
Thanks but have had mains and battery disconnected?

Trev, October 2012
remove power from it,it will die,then reconnect power

gts, October 2012
Hope you not in there with mains power on trev?,

Sounds like you have tamper splitter, bet shock sensor is on zone three.These are a great fix for EMI/RFI ( interference ),and for identifying a global tamper fault.

See you can split the tampers from global only into specific zones,

Resetting one? Good question :)

e manno, October 2012
Thanks I've had a good look and the markings on the circuit device are 12v 0v supply. Zone 1 2 3 4. N/C N/O c relay,no three zone red light on.I've tried resetting with engineering code and all four user codes. Nothing, tamper and call engineer lights are still lit.I know i caused the tamper fault when I replaced the shock sensor but I was able to reset after i changed out the battery, got tamper then and reset with engineers code.i'am now at a loss?.

Trev, October 2012
Not being funny but "I Think" is what the Captain of the Titanic said.
Can we have full details as numbers and lights equal a diagnostic sequence we can address.

Alarm, October 2012
Thanks the tamper and call engineer lights are lit,the red light is inside the box on a small device with wires.I think the light is above zone 3

Trev, October 2012
This red light on circuit board?

Is it on main board or separate board?

If it small board with four LED's, it's a global tamper splitter and it needs resetting,does this sound like what you have?.

Answer Alarm's questions though, we need to know the panels status and what's going on.

e manno, October 2012
Check the tamper on the new sensor.
Also the lid tamper cannot set correctly if bent.

Is there a zone number on as well at the same time? Is it the tamper or fault light?