Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

Burner and pilot light go out together?

thermocouple or gas valve the click is the solenoid on gas valve lifting

WILLIAM MCDONALD
November 2006

Thanks William, but...
Thermocouple ; thermocouple re-router ; pilot burner ; and GAS VALVE all replaced within last 6 weeks. Boiler was working perfectly for 5-6 weeks, after gas valve replaced, and has been giving above problem for past 2 weeks!
RSD, November 2006
BG MIKE,

Glow-worm Space-Saver 40B MK 11.

The pilot injector is new as stated above. I am in the process of flushing, and de-sludging the system, as the water is black.

I am now suspecting the thermostat, but I have run an electrical check on the system and it proves that all is well!

RSD, November 2006
WHAT BOILER IS IT?, POSSIBLY PILOT INJECTOR BLOCKED OR BURNER LIFTING OFF DUE TO VITIATION.

BG MIKE, November 2006