andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

within ten mins of starting cen/heating hp 3 bar plus?

wthin ten mins of starting cen/heating hp 3 bar plus
ed, February 2013
expanssion tank in boiler needs re inflating. it holds air in the tank so when the water heats up it will expand into the tank keeping the pressure stable. if there is low air or tank is faulty it will not work as it should causing rise in boiler pressure. it can be inflatted using a car air pump. pressure should be around 1.5bar with the water drained from the boiler. u cant inflate it with water in the boiler

kash, February 2013