GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

How can I fix my alarm veritas r8?

Hello . I have just installed a veritas r8 alarm , when I set the alarm the zone with the door contacts on lights up on the key pad saying that the zone has been activated stopping the system from been set .
Msmith, July 2013
its a very simple prob to find hope you sort it

gts, July 2013
Ok I will short those out which will prove the cable as well . Well hopefully with your help I might just get it sorted thanks again

Msmith, July 2013
the only switch you need to check is the door switch,its a glass switch and is very broken if you are a bit rough when fitting it,remove the switch short the switch wires then see if your panel resets ,if it does then the switch is open circuit and you need to replace it and as I said check that you have not wired the switch wires to the tamper circuit in the infra-red beam if you have done this the alarm will trip every time the beam picks you up

gts, July 2013
I will check the cable thanks doubt it's the actual switches as there are 3 of them 1is on a different circuit thanks for your help .

Msmith, July 2013
sorry,open circuit ,wire cut or switch broken

gts, July 2013
Thanks I will check the pir connections . O/c ??

Msmith, July 2013
will be on line all night

gts, July 2013
get back to me let me know how you get on

gts, July 2013
and check the wiring in the mag con too

gts, July 2013
then the wiring or your door contact is o/c mate check the wiring in the beam that u have not wired the switch wire to the tamper con in the beam

gts, July 2013
Thanks, Yeah I have checked the contacts and if I short out the zone they are wired into the panel does set as normal literally pulling my hair out :) also have you ever came across a pir that sets the alarm off when it is unset I have checked it isn't programmed to tamper , panic or fire and set an unused zone to these for fault finding

Msmith, July 2013
check the door contact and the wiring ,if you don't have a test meter just short out the door contact terminals in the panel and see if it will set now,beware the mains power

gts, July 2013