Hotpoint WD440 no load on the heater element?
Hello
We have a one year old Hotpoint WD440 and the dry cycle isn't heating up. I posted a question saying as much and it was suggested I test the element and the load during the dry cycle.
I checked the element and there is continuity.
I carefully taped a voltmeter to the spade connectors and I am getting no load during the dry cycle. Occasionally I see 5, 15 and once 44 volts register but only for a second. One thing I did notice is the element has a sensor of some sort connected by a 2 pin plug. Without this connected the washer goes into mode which can only be terminated by unplugging the mains.
Any suggestions?
Robert Moss, November 2006