Vokera 16e pcb?
I am hoping someone could help with vokera mynute 16e, it's not working, no ignition or fan starting.
I followed manual initial electrical checks to fix ignition problems. The boiler will not reset.
1- Ensure system pressure is 0.5 bar or above(done)
2- Carry out routine electrical checks (see below)
3- Disconnect external controls from appliance and insert link-wire between terminals 1 & 2 (done)
4- Fit ‘jumper’ to JP1 to cancel timer delay if necessary (not done)
5-Turn boiler thermostat to maximum(done)
6- Reset boiler mode switch if required(does not do anything)
Initial electrical check
1- 230v L&N of terminal strip? (Done => ok)
2- 230v J2. 7&1? (Done => ok)
3- 230v J2 6&1 (Done => ok)
4- 230v J2 5&1 (Done => NO 230V)
solution: check external controls or link between 1&2 terminal strip.
1- link between 1&2 terminal strip (Done => ok)
the cables that go to the pcb 1&5 show to 230v on the terminal strip, but nothing on the pcb.
Any ideas what the problem could be? I suspect the pcb needs changing but it's quite expensive.
Thanks in advance.
Muz
Muz, March 2016