Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

my Glow-worm ultimate boiler will not light?

How can I repair my glowworm ultimate boiiler fan is running and ignighter is working but boiler will not fire up
really grateful for any help
The serial number is 980008390
Steve, January 2007
I have the same problem. I had an engineer out yesterday for the yearly cleaning. Up until then it was working perfectly, I didn't switch the heating on until last night and now it's making a ticking noise but the pilot light won't come on. Now there's no heat or hot water on a weekend with a house full of people with stomach flu, just typical!

Anyone have an idea of a quick fix 'til Monday and I can call the engineer back out.. that isn't too technical?

s.g, October 2008
More than likely it is a blocked pilot injector, these seem prone to blocking when they get over 8 years old. The pilot assembly and tube has to be disconnected and the two tiny holes in the pilot injector need to be unblocked with a small peice of wire or needle.

Brad, February 2007
There is a good chance your pilot jet is blocked to check if you get a flame aroung the ingnition point where the spark is for about 10 to 20 secs and the main burner lights then when you remove the flame if the pilot does not stay alight the the piolt jets are blocked hope this helps.

Bonesy, February 2007
I have the same issue too - The spark comes on and i can see a very tiny blue light but thean thats all - The fan runs but it seems it does not complete - Last time i had this issue the engineer changed the Ignition PCB. I guess I just need to know where to find the PCB so i can change it.

Rav, January 2007
link Click here to see other fixes for Glow-Worm.