Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

Baxi 130He problems with 00?

Hi my boiler was flashing L7 and L8 replaced the flow switch which stopped the leak but now it is stuck on 00 and nothing I do starts the boiler up. No leaks on radiators have tried reset and all other options in book supplied would appreciate any other suggestions. Many Thanks Lynne
Lynne, February 2007
Do you have an intellistat fitted? If so, ensure the boiler hasn't "forgotten" about it. On mine, if the intellistat is there but switched off in the boiler setup, it won't do CH, only DHW.

It managed to forget about the intellistat after a recent extended power failure. Enabling it in the config sorted it.

Martin, March 2007
Yes it is on 1.5 thank you for replying

Lynne, February 2007
is the pressure up to 1.5 bar

hi-spec plumbing, February 2007
link Click here to see other fixes for Baxi.