andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

Fisher and Paykel smart drive 608 6.5kg control module problem?

The unit has a mustard coloured module with a 4Amp 240V PCB mounted Fuse just after the 240V mains power input. This fuse has gone bang.

Can someone help me with what the resistance values of the wires connecting to this module to find out if fault is a pump or a coil etc

If there are any other suggestions they would be greatly appreciated.
David, February 2007
Check the resistance of all loads that are external to the module. If the module does not show physical signs of damage I would would carry out a resistance check on solenoids, motor, drain pump,etc.
The root cause of the fuse blowing may be either a load fault (a short or very low resistance) or an earth fault.

garryk, February 2007
link Click here to see other fixes for Fisher and Paykel 608.