Most likely the one-shot thermostat is open. Disconnect machine from mains supply then check the stat using a multimeter set on the ohms range. If the stat is OK you will read a few ohms when testing across the stat terminals. If you have overloaded the machine capacity the one-shot stat may have tripped due to overheat in the drum (a one-shot is a non resettable thermostat that protects the machine against gross overheating). If the one-shot is open circuit you need to replace it with a new identical part
garryk, February 2007
would check the thermostats 1st if need a set email us