Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Connecting new external sounder to Optima XM6 alarm panel?

Hi - I have purchased an Odyssey Series external sounder to replace a faulty sounder box connected to my Optima XM6 alarm panel. The terminals in the alarm panel are marked -

Strobe +,
Strobe -,
'T' Tamper Return,
'A' 0 volts,
'D' 12v +ve,
'B' Trigger on.

Many thanks.

Alan.on m
Alan Vickers, February 2007
bell box connection panel connection
A goes to terminal D 12v supply voltage
B goes to terminal B 0v trigger in alarm
C goes to terminal T tamper return
D goes to terminal A 0v supply voltage
S goes to terminal - of the strobe terminal

Chris AXIS Fire & Security, March 2007
Thanks pete. I already have the wire colours as connected to the Optima XM6 alarm box. What I need is what are the corresponding terminals on the Odyssey External sounder to connect them to.

Alan.

Alan Vickers, February 2007
you will need to see which wires are used for each function on the old box.
Wire colours are not made obvious in alarms , ie red is seldom +ve, black is seldom -ve (or 0v), its usually a random thing for added security.

Pete, February 2007
link Click here to see other fixes for Optima XM6.