GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

pull chord switch?

i have a triton electric shower and the pull chord electric switch that it is turned on and off by has a burnt live wire on the load port, what would have caused this. Needless to say the shower does not work now.
Ian, February 2007
In my experience its usually a loosely clamped wire. Also check the kilowatt rating of the shower to see what Ampage switch you need. It's nothing to do with the shower itself.

A 9.5kW usually needs a 40A Switch and a 10.5kW 45A.

JD, March 2007
Possibly caused by a loose connection, or maybe the switch not correct one,you need a 45 or 50 amp d/p switch.

Pete, February 2007