Suzanne asked ... Washing programme stops after 3 minutes?    |    Rif asked ... Kenwood Dishwasher KID60S20 leaking from front?    |    Fraser asked ... Spares for power craft ppcs 38cc?    |    FB asked ... Toyota Yaris Speed Camera Warning Beep?    |    Ela asked ... Worcester 30 Cadillac combi boiler won’t fire up and the EA?    |    Click here to ask your question

vokera 24 still running when timer off?

vokera 24 combi works fine but sometimes when auto clock cuts off timer the boiler carries on running and then stops and then starts again.Any ideas??
darren Benson, February 2007
Please ignore my answer- it was wrong .. just checked the manual, (this model has a motorised diverter valve driven by the microswitch operation).

cd, February 2007
Maybe an intermittent fault on hot water microswitch? (boiler thinks that there is hot water demand, but diverter valve is in central heasting demand position, so radiators get/stay hot).

Does turning down the domestic hot water temperature (on the boiler controls when it is fired up wrongly) turn down the flame, or does turning down the central heating temperature modulate the flame during this condition?.

If the first case then it may be the microswitch, if the second maybe the timer itself is faulty?.

cd, February 2007
change primary thermistor

mr gas, February 2007