inside your machine is a fill level sensor, (switch with a pipe on it) they tend to get blocked up over time, follow the pipe down to the wider bit, this needs cleaning out. other reason for this fault is an inlet valve is not closing after filling, but first fault is more common
pe2e (ex appliance engineer), February 2007