hi alison these are the light flashes
These codes are reading from the top neon down.
F01....OFF, OFF, OFF, Flash, OFF.
F02....OFF, OFF, Flash, OFF, OFF.
F03....OFF, OFF, Flash, Flash, OFF.
F04....OFF, Flash, OFF, OFF, OFF.
F05....OFF, Flash, OFF, Flash, OFF.
F06....OFF, Flash, Flash, OFF, OFF.
F07....OFF, Flash, Flash, Flash, OFF.
F08....Flash, OFF, OFF, OFF, OFF.
F09....Flash, OFF, OFF, Flash, OFF.
F10....Flash, OFF, Flash, OFF, OFF.
F11....Flash, OFF, Flash, Flash, OFF.
F12....Flash, Flash, OFF, OFF, OFF.
F13....Flash, Flash, OFF, Flash, OFF.
F14....Flash, Flash, Flash, OFF, OFF.
F15....Flash, Flash, Flash, Flash, OFF.
f16....OFF, OFF, OFF, OFF, Flash.
F17....OFF, OFF, OFF, Flash, Flash.
F18....OFF, OFF, ON, OFF, OFF. Fault on control board, check Eeprom.
Faults without error codes. If the motor is O/C the machine will not fill or operate.
The digital display models will generate the actual fault code, ie; F01 etc.
and this is what they mean
widl codes - light flashing from left to right are numbers 1-4
f01 light 4, motor triac
f02 light 3 motor, jammed/ tacho
f03 lights 3&4 Ntc fault
f04 light 2. pressure sw stuck on empty
f05 lights 2&4, pressure sw stuck on full
f06 lights 2&3, N/A?
f07 lights 2&3&4 heater relay
f08 light 1. heater relay
f09 lights 1&4 eprom/setup error
f10 lights 1&3, pressure switch not sensing
f11 lights 1&3&4, pump/draining error
f12 lights 1&2, communication error
f13 lights 1&2&4, dryer ntc/ fan motor
f14 lights 1&2&3, dryer heater
f15 lights 1&2&3&4, dryer heater relay
f16 N/A
f17 light 4, door lock
f18 light 3 comms error (3 phase motor) power board
f1 and f17 share the same light
Anymore questions http://www.freewebs.com/msdapudsey1
Just go to the forum
phil grimshaw, April 2007