Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

My Worcester 24i Junior is not working?

My Worcester 24i junior isn't working, there is a 4 flash per second on the light. There is no hot water or heating. This has been happening for a while but it used to work after switching it off at the wall for around an hour, but now its not heating at all. The pressure is fine, at just above 1. Please help!
Jenny M, May 2007
fan runs all the time got hot water but no central heating could the pump be faulty

John, April 2013
Fan come on but the boiler does not ignite.

arthur, January 2011
what you need is a very big HAMMER

TOP PLUMBER, December 2010
my boilers worning light is flashing and no hot water

rachel, October 2009
my worcester 24i junior packed in this morning. the fan comes on but its not igniting. had a corgi reg bloke to look at, he changed the air pressure switch, cleaned the rubber piping, fan and flue but it made no difference.. any ideas??

Harry, October 2008
When turn central heating on, works for about 15 minutes, then light flashes once per second. Once pressed to reset it works for another 15mins then cuts out. After 2nd reset it stays on ok.
Hot water ok except when run the bath - cuts out after 10-15 mins of running water - ok after reset

malcolm, September 2008
Link out. dont so dangerous to link out anything unless u know what ur doing

rob engineer, February 2008
The manufacturers book lists 7 possible faults for your boiler?

I know through experience of these boilers that there is a fault with the water pressure switch which causes several faults. Worcester tech line has confirmed this to me. They have had lots of feed back from engineers.

The easiest way to check it is to have a competent person (CORGI eng) link out the pressure switch. There are only 2 orange wires on it.

Be advised! DO NOT leave the switch linked out if its the fault. New ones are readily available at parts stockists.

Baz (CORGI Eng), May 2007
Have you checked your manual for the fault identification ? It should give you a pointer towards the likely source.
From memory that fault may be a fan or flue problem. (i may be wrong). If it is you will need a corgi registered engineer because it involves going into the burner chamber(gas/fumes).

T.h.s, May 2007
hi if you use your instuction booklet, look under faults it will tell you what the fault is, coraspond the flashing lights to the ones on the fault page.

cheeky chap, May 2007
link Click here to see other fixes for Worcester 24i.