GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

when?

when the boiler isnt on it stays at 1bar on the dial,how much should the pressure go up when the heating is on
j helliwell, June 2007
hi-spec is correct but there is bit more to it

if you only had one or two radiators then there is not a lot of water to expand so the smaller the volume of radiator water, the smaller will be the increase in pressure.
If you had say ten radiators then the inbuilt pressure vessel may not have suffient internal volume to accomodate this larger amount of water expansion. Sometimes you may need a second vessel. Read the instructions for the appliance it will be tell you about maximum system volume. Average about 60 -80 litres. (from memory)
average increase is from 1 to 1.5 bar --but it does vary

dave broadbent, June 2007
only to about 1.2 bar

hi-spec plumbing, June 2007