3 hours ago Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    Click here to ask your question

what part causes WHITE knight gas dryer to switch off heat after 4 minutes?

WHITE KNIGHT gas dryer BG 442/1 SERIAL No 9729 034276 switches off the burner after 4 minutes. A erattic clicking can be heard like a selenoid ,as the gas igniter also clicks 2-3 times to try & relight the gas. nothing reignites so contnues to tumble cold. can restart via the timer ,only it runs hot for less time than before. what part/s do i need to replace?
PETER PRATO, July 2007
The same thing happened to my BG 437. It tumbled but gas stayed on for 10-15 seconds each time on the cycle with no heat being produced. I tested the thermostats - all working and then replaced the FFD (flame failure device) this is an electrode situated in the path of the gas flame. Has worked perfectly after this. It is held in by one screw and got at by removing both small panels at the back of the machine

john kirk, January 2008
link Click here to see other fixes for White Knight BG 442/1.