GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

How can i check which each of the sensors are for my optima xm6 alarm?

I am wanting to know how to find out which zone each of the sensors are on my optima xm6? (so you can press omit and then numbers to switch off different sensors)
Tom, August 2007
Instructions ?
http://www.instruction-manuals.co.uk/category/MISCELLA/optimaXM.htm

Richard Thorp, August 2007
Hi
I've just rewired my Concept Optima XM. It's a slightly different model to yours, but this is the procedure for mine.
I've fitted a few different models over the years, and they all tend to work the same way.
If you use the "Walk test" - then "trip" a sensor - door contact or PIR - the relevant zone light will light. You can use this to see which sensors are on which zones.

From "Day" mode, press PROG [All lights show], enter the Customer Code [Day and Tamper show]. System in Customer Programming mode.
Press 0 for Alarm Tests [Day, Tamper and Attack show]
System now in Test Mode.
Strobe test - 2, 0 to stop.
Bell test - 3, 0 to stop.
Low Sounder test - 4, 0 to stop.
High Sounder test - 24, 0 to stop.
WALK TEST - 5, 0 to stop.
Reset, reset - to go back to Day Mode.

Hope this helps
Richard

Richard Thorp, August 2007
Hi Tom,
You need to do a walk test.
To do this you PRESS PROG BUTTON THEN ENTER YOUR CODE.
PRESS 5 , THIS PUTS THE SYSTEM INTO WALK TEST MODE.
ACTIVATE YOUR SENSORS TAKING NOTE OF WHICH ZONE IS CONNECTED TO WHICH SENSOR(S).
WHEN YOU'RE FINISHED PRESS 0 THEN RESET , RESET.

Hope this helps

Johnny, August 2007