Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

ravenheat rsf84et playing up please help!!!?

I turned the CH on last night and the pilot light didnt ignite, ive had this problem befour and it was just a faulty ignition which still cost me a fortune!!, This time the fan isnt coming on, i can hear the pump running and the boiler lights are on but the fan is defo not running.any suggestions PLEASE!
carl, September 2007
the thermistors on this boiler are prone to going, try the primary thermistor first. if not then possibly ignition board??? i can only give you the common faults with this boiler but without looking at it, it could be anything!!! good luck

webmaster, September 2007
this is an ignition sequence problem ,could involve pcb, air pressure switch,or the fan itself, you need to determine if you are getting 240 volts to the fan, if you are then the fan is def faulty,if not then air pressure switch or pcb are suspect

alan, September 2007
link Click here to see other fixes for Ravenheat.