Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Marc Nollid asked ... Nissan Micra mk 5 2018 rear seat mecanism?    |    Maggie asked ... New Home 535?    |    Click here to ask your question

Micron 60FF?

I have a micron 60FF the boiler lights and the burner led lights, it then shuts down after appx 30 secs, and goes through the process again. I have replaced the pcb and temperature limiter to no avail.

Does anyone have any suggestions, could it be the thermistor?
Steve F, October 2007
Hi, a bit late I know, but for future reference....I had this problem, it was a faulty valve in the airing cupboard. Its one of the electrically controlled ones, it wasn't opening and so the hot water wasn't able to get into the tank, the boiled was just heating a tiny bit it water in the pipe and so it was thinking it was up to temperature after a few seconds. I replaces the value (just the motor part on top, not the acutal pipe part) and hey presto it worked perfectly.

hth

G

Cyril the Plumber, October 2009
link Click here to see other fixes for Protech 60FF.