GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

sealed system?

I don't appear to have a leak, however my combi central heating system keeps losing pressure.
Kevin GOGGIN, January 2008
hi kevin.

the problem with your system is the expansion vessle fitted in to your boiler possiblly needs to be recharged with compressed air. usual pressure is 1 bar or 15 psi, you can do this using a foot pump or a bicycle pump would do.
the vessle is usually located at the rear of the boiler if its a combination or perhapes in the airing cupboard if it a conventual system.
the vessle is coloured red.
hope it helps..