Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Nick asked ... Oven spark Continuing after lit?    |    Click here to ask your question

sealed system?

I don't appear to have a leak, however my combi central heating system keeps losing pressure.
Kevin GOGGIN, January 2008
hi kevin.

the problem with your system is the expansion vessle fitted in to your boiler possiblly needs to be recharged with compressed air. usual pressure is 1 bar or 15 psi, you can do this using a foot pump or a bicycle pump would do.
the vessle is usually located at the rear of the boiler if its a combination or perhapes in the airing cupboard if it a conventual system.
the vessle is coloured red.
hope it helps..

terry ellis, January 2008