1 hour ago Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

High pressure in my ferrolli boiler?

My boiler was reading 3bar.I had the expanssion vessel replaced but the pressure is still rising.Any further ideas please
Darren, January 2008
the vessel has been replaced and the filling loop disconnected and the pressure is still high.does this mean that i will have to get the heat exchanger replaced?

darren, February 2008
3 reasons for pressure rising, expansion vessel, plate heat exchanger passing mains water or filling loop by passing.

Justin, January 2008