GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

How do i replce Switchmaster VA 1 Midi Valve with a Honeywell?

The Switchmaster 3 way valve on my CH is not working properly. I can't find one anywhere. If I have to replace it with a Honeywell V4073A, can anyone tell me how to wire this? The Honeywell has five wires, the Switchmaster had six.
Terry, January 2008
ne this discussion forum
(http://myreader.co.uk/msg/1391136132.aspx)
I found a wiring translation.

I wired this in after the plumber did the pipework,
and its fine. Be a bit careful to ensure the neutrals are commoned

Here is the wiring from the other forum, which I used sucessfully.
s promised:

Switchmaster VA1 --> Honeywell V4073A --> Connection

Red --> Orange --> Live to Boiler & Pump
Orange --> Orange(Link to above) --> Tank Stat HW on
White --> Grey --> Tank Stat HW off
Yellow --> White --> CH on (from room stat)
Blue --> Blue --> Neutral
G/Y --> G/Y --> Earth

robin clark robin48gx at gmail dot com, November 2009
I have worked out the wiring to covert between the 2 valves but in order not to move any pipes I would have to install the honeywell upside down (head at the bottom).

Is there any issue with this? I assume there is only a motor inside the head and the seal to the actual value would work in any orientation, yes?

David, March 2008
Terry. No I have done nothing about it yet as the system seems to work without it. I guess the problem will come when I switch the CH off. then the water heating will not work.
The switch must be jambed OPEN.

Ernest Wisner, February 2008
Ernest, I haven't changed mine yet. I've got the wiring sorted for a Honeywell exchange now, but don't know if the pipework is a direct swap out or not. Have you done yours yet.

Terry, February 2008
Can this replaement be made without changing the pipework?
Mine has packed up today 29 Jan 08

Ernest Wisner, January 2008