1 hour ago Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

Ferroli Modena 102 Temperature Problems?

I have problems when trying to adjust the temperature of both the DHW and the CH. Both are very high and do not seem to respond to adjusting the dials on the front control panel. Also the boiler pump and burner continuously cuts in and out at the same time when on CH only. I'm sure the pump is supposed to run continuously with the burner cutting in as required to maintain the return temp. (Unless someone calls for hot water)

Service engineer previously came out and changed the venturi, removed the flue discharge restrictor, cleaned it up and changed the thermistors. He said the only other thing would be the pcb ?

I don't think it's a problem with any blocked flow restrictors etc. as we have soft water in our area.

New pcb's are very expensive as genuine parts and i would like some assurance, if possible, that this is the problem before paying more money?

Also I have found a website (CET Ltd.) which sells second hand pcb's for £50. If i get this does anyone know how easy they are to change ? Thanks in advance for any help !
Rob Billingham, January 2008
Thank you .For your answer ,I was having the same problem .Now I will look for if I can change it by my self or do I have to call an engineer.How much it will cost ?

FK, September 2008
Get yourself a Worcester.

Josh, January 2008
OK i will answer my own question as nobody else has !

The service eng. came out. It was the CH temperature sensor. This was causing the temp to overheat and cut out the pump. During the cut out period (until the boiler cools down sufficiently) the HW is also not operational. The DHW control is flow dependant and will only really operate properly during maximum draw off this was why the DHW temperature seemed high. He changed both sensors and it seems to be running OK.

Rob, January 2008
link Click here to see other fixes for Ferroli.