Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Kelvinator "Gentle Annie"?

Very Slow filling of cold water into machine when set on cold
Clarke Taylor, January 2008
Had exactly this problem yesterday. Had no idea how old these machines were! 1984. Anyway, slow fill in this case was caused by the a previous repairer switching the wires between the hot and cold solonoid valves. The hot valve has a restricter in it, the cold not.

Once switched back, it was fine. The 2 cold water solonoid wires have "cool" colours, the hot solonoid wires are "warm" colours.

Luke, January 2011
have you got good water pressure to the taps in the rest of the house?(if yes) suspect inlet pipe to machine, turn off,water filler tap,remove hose from machine end,HOLD end in a bucket OPEN tap,pressure SHOULD BE THERE, is your tap one one of these self cutting type ? guarantee the tiny stupid hole is blocked change the valve.check and clean filter screens on the inlets to water solenoids

wirecutterman, January 2008