andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

sime 80 combi boiler?

Hi,
Hope you can help. We have no hot water but plenty of central heating. Except top radiator not filling.
neil, June 2005
hi neil i suspect the diaphragm in the diverter valve has perished you may have to replece the complete diverter valve if the diaphragm kits are not available. regarding the upstairs radiator try topping up the boiler pressure to 1.5 bar and venting air from the rad hope this helps

joe waldron, June 2005