Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

pilot light comes on but cannot get boiler to light?

execell vokera
hargr6@aol.com, February 2008
faulty gas valve 90% cert if the boiler is over 10 years old

d m heating 07788785037, February 2008
The boiler will not operate the gas valve unless it knows that water is flowing through the boiler (flow switch) and that that air is flowing (differential air pressure switch). It could be the pump, fan, or switches at fault (assuming that the system has water pressure). The pilot will stay lit for a while even if there is no electricity to spin fan to scavenge the combustion chamber, no electricity stops the boiler working too.

c, February 2008