Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

What can the fault be with constant running on lynx 2 combi boiler?

I have a Potterton Lynx 2 combi boiler that has had its fair share of problems over the years.It now fires continuously with the result the pressure rises, the prv release a bit and then lasts a couple more days before it hits low pressure and needs topping up. The gas board have replaced the prv , the pcb, the disc thermostat and the thermister , the gas valve , all to no avail .It works until there is a pressure build up .I do not think the PCB is at fault and think the culprit is a faulty thermostat .Any suggestions would be welcome
David Walker, February 2008
sounds like the hot water flow switch is sticking and requires replacing this can be checked by unpluging and seeing in boiler turns off
The thermostates will not cause boiler to fire without signel from heating or hot water side to do so

tony, February 2008