Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

Hi can some one help vaillant?

Hi can some one help i have a vaillant boiler.And it has stopped working the fuilt message is f29 if you now what f29 is please help the make is vaillant ecommax

thank you
kan, February 2008
Thanks so much!! This 100% works!!

lee, February 2013
my boilernot workin keeps getting f28 or f29 i do have gas please help

daz, January 2013
Just wanted to say thanks as well as it helped me ignite my boiler too! So thanks!

Hins21, December 2010
It works..Thanks a lot! saved me on a freezing winter night.

Thanks
Arnov

Arnov, November 2010
this worked, just wanted to thank you as it was helpful. cheers.

a turk, March 2010
F29 is that the boiler has attempted to ignite and after the third time it has still failed so locked out. If you press the manual ignition button ( flame with a cross through it - hold it in for a second ) then the boiler should ignite.

This is the same fault i have with a Turbo Max and what the manual says the fault code is. It is an intermittant fault so
I had my boiler serviced and it was suggested if the problem re-occurs then replace the ignitor/electrode. This is proving a bit tricky with getting the right part number etc.

Hope this helps

Mikedw, March 2008
link Click here to see other fixes for Vaillant.