cold pressure over 2.5 bar on vokera Excell 80sp?

I have a vokera Excell 80sp boiler and the pressure when the heating is cold is 2.5 bar. I think i need to release some pressure but don't know where the pressure relief / discharge valve is. Does anybody know?
Jamie, March 2008
hi, you should not use the prv to release pressure, there should be a drain off valve on one of the pipes leading to one of your rads you would be better off connecting a hose to this or just draining it into a container to release the pressure.

gary.wright53@googlemail.com, March 2008
drain pressure via a radiator bleed valve if no other means available

ck, March 2008