new gas valve fitted but wont stay alight why?????

i have tried everything including a new gas valve but still cant get the pilot light to stay alight vokera excell 80sp boiler new thermo couple fitted also.
duane rowbotham, March 2008
if when the pilot lights and after 30secs of holding the gas valve in the pilot goes straight out on releasing then you will have an overheat stat fitted in series with the thermocouple this needs a continuity test to determine if it as operated and needs replacing

combiking, March 2008
Your fan may not be slow running when there is no demand. This causes the pilot to suffocate after a while. A tell tale sign is the lack of any fan noise (can be very quiet) when there is no demand, and the top of the boiler being warm after a period of no demand.

Likely causes are a dry joint on the metal clad slow run dropper resistor, or a broken flow microswitch. Try operating the flow microswitch with your finger, it should have positive clicky operation like the DHW microswitch. Check for AC volts (careful, mains voltage) across the leads going to the fan when there is no demand.

c, March 2008
from the symptoms you describe it sounds like the thermocouple has either not been put in correctly or it has gone. replace with same type or universal one should sort it out.

gary, March 2008
link Click here to see other fixes for Vokera excell 80sp.