Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

ideal isar 35he wont fire up L-F fault?

recently fitted few days ago got inlet gas pressure of 24mb
filled and turned on fired up for about 10mins
switched it off
now when u turn it on displays c with burner light flashing but doesnt light up switches to d but after 3 attempts shuts down with L - F fault code
any ideas? want comissioning?
dave burns, March 2008
when the the boiler attempts to fire what is the pressure

matt the boiler man, March 2008
standing pressure
cos the boiler wont fire up

dave burns, March 2008
24 mb working or standing pressure ???

matt the boiler man, March 2008
condense trap/pipe is ok
i have purged the gas and have 24mb at the inlet of the gas valve
????

dave burns, March 2008
flame failure.
gas supply problem-condesate trap/pipe blocked?????

iain, March 2008