andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

how can i fix my glo-orm 30ci boiler?

my glo-worm 30ci boiler first started showing DL on the display and is now showing f1 faults and nbody seems to know what these mean, which is no help to myself as i now have no heating or hot water, and have not had any since the weekend, water pressure is going above what it should do, so looks like boiler is overheating any advice
pauline, April 2008
F1 is 'Ignition Lockout' ie. either no gas or no flame detection

As for the system water pressure, that boiler should not foault on this until the water is outside of 0.5 - 2.7 bar pressure.
Normal system cold pressure should be about 1-1.5 bar, if when hot it exceeds 2.5 there may be also a problem with your expansion vessel.

T, April 2008