46 mins ago mike asked ... F+p 913t dishwasher?    |    Emma asked ... Foot pedal smoking?    |    Morne asked ... My defy dtl 125 toploader?    |    Ernie asked ... How to fix gearchange ldv maxus van 2006?    |    Cuckoo asked ... Changing batteries on a fixed bt corded phone?    |    Click here to ask your question

fault code f.25?

my boiler wont work cause of a fault code f.25. This tells me in my book that the system pressure is too low, Can i fix this myself and if so how? vaillant ecomax 824/2 e
Leanne Pace, April 2008
yes, locate your system water filling loop (usually a flexible stell braided hose with a small black handle) slowly open this, while keeping an eye on the boiler system pressure, raise it to 1 - 1.5 bar, if you exceed it drain of excess water through a radiator bleed vent.

Most of the vaillants come with a filling cycle you can run through afterwards to clear any air that maybe in your heat exchanger, run this filling & venting cycle before running your boiler.

T, April 2008