We have 33 questions about fixing 'myson velaire'

Myson velaire oil pump?

I have an old Myson Velaire oil boiler and the oil pump has seized is there a replacement out their that fits as the original is now discontinued?


done

myson velaire vitesse 60/80 balanced flue?

Can anyone help me source a Flue Terminal for my MYSON VELAIRE VITESSE 60/80 BALANCED FLUE/ CONVENTIONAL FLUE OIL BOILER. Boiler is 22 years old and still running perfectly only bit that has broke ... more


Myson Velaire PJ 70/90 noisy fan motor?

Myson Velaire PJ 70/90 noisy fan motor. I suspect worn bearings. can I replace the bearings or replace the complete fan motor


how can i start myson velaire boiler after it ran out of oil?

now refilled the oil tank but i keep getting lock out on the boiler


How can the fan be repaired? Do I need a new circuit board?

The fan doesn`t switch on before the burner fires up. Also, when the boiler switches off, the fan doesn`t clear the exhaust gases before it fires up next time. This causes a build up of fumes and the ... more


done

How to fix Myson Velaire boiler?

My Myson Velaire boiler will not fire up, can you help with some suggestions


Change to a Balanced Flue from Conventional Flue?

I need to change my conventional flue to a balanced type. I am having difficulty locating a balanced flue for my oil boiler. It is a Myson Velaire Pressure Jet 70/90. Can anyone advise? Is it possible ... more


done

new burner for myson velaire 60-80 oil boiler?

the myson oil boiler has a inter 2000 edgbd burner on and nee to be replaced with a new buner, can you advise of what the replacement should be and how much. regards mark


myson velaire oil fired pressure jet boiler 70/90?

Hi there, I am currently re plumbing my central heating system which had a leak somewhere which is currently gravity fed, and i am putting in a pressure system as I want the header tank out, but i can ... more


done

Spare parts - Myson velaire vitesse 40/50?

Looking for limit switch warning light, consists of lens, bulb, some sort of transistor, bulb holder and 2 cables. Any ideas?


done

myson velaire 50/70 boiler?

have set up as per the original manual.co2 10.51%,150 psi,air damper no.5 but flue gas temp. very high, 431 deg c vs 300 in manual.any suggestions to explain/correct the difference?


done

Myson Velaire Blows Fuses?

My 1988 Myson Velaire (kero) is blowing fuses. My electrician has isolated it to the control panel but said he didn't know anything about them so wouldn't take it apart. I'm hoping to diagnose the pro ... more


done

myson velaire 60/80 balanced flue oil fired?

how do I bleed this boiler model - myson velaire 60/80 balanced flue boiler oil ran out has been left to settle for 24 hours