Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

My Potterton Oil Boiler Gauge is losing pressure?

Its a floor standing oil fed boiler.Its been like this for 4 weeks,im not sure if this means a leak somewhere or a gauge/pressure problem?
stuart, April 2008
hi Stuart,

Yes a leak is a possibility, or when your heating system is hot, does it ever reach a pressure of above 3bar? if so the safety valve may be lifting and letting water out, this would be a sign that your expansion vessel needs charging or replacing.

Also, just check the safety valve is not dripping, sometimes after a lift (maybe someone disturbed it) dirt gets caught under the seat of the valve and it will contiue to drip forever until your system is drained and the valve cleaned or replaced.

T, April 2008