andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

Filling up my boiler-Glow Worm30HXI?

I have a fault F5 showing on my Glow Worm 30HXI boiler. How do I fix this. I have no instruction booklet. Thanks H
H Garbutt, April 2008
F5 is an overheat fault, due to maximum temperature being exceeded

Check both the overheat stat and ch thermisters
Possible air in the system, make sure system pressure is 1-1.5 bar and all air has been bled from the system
Check pump is working correctly and does over run when boiler reaches temp.