Andrew - C asked ... Stannah 400?    |    Liam asked ... Belts for old WEBB Mower?    |    Leith asked ... Bosch Classix Type WKM41 front loader washing machine?    |    Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    Click here to ask your question

Filling up my boiler-Glow Worm30HXI?

I have a fault F5 showing on my Glow Worm 30HXI boiler. How do I fix this. I have no instruction booklet. Thanks H
H Garbutt, April 2008
F5 is an overheat fault, due to maximum temperature being exceeded

Check both the overheat stat and ch thermisters
Possible air in the system, make sure system pressure is 1-1.5 bar and all air has been bled from the system
Check pump is working correctly and does over run when boiler reaches temp.