Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Susan asked ... How can I stop my steam iron spraying water with the steam?    |    Click here to ask your question

Engine shuts off when you let the trigger go?

I have a Craftsman 2600psi (6hp OHC) pressure washer that shuts off every time I let go of the spray nozzle. Is there some kind of adjustment on the pump that will allow it to run while not spraying? Thank you any advice.

Brent
Brent Howard, April 2008
Pump not required to run as it's built up enough pressure. Only runs when the pressure falls below a minimum which usually happens while you have the spray activated

wetone, May 2008
link Click here to see other fixes for Craftsman.