4 hours ago Rif asked ... Kenwood Dishwasher KID60S20 leaking from front?    |    Fraser asked ... Spares for power craft ppcs 38cc?    |    FB asked ... Toyota Yaris Speed Camera Warning Beep?    |    Ela asked ... Worcester 30 Cadillac combi boiler won’t fire up and the EA?    |    Alan asked ... Problem with JCB 3CX transmission?    |    Click here to ask your question

Baxi combi 80Eco heats radiators when selector switch on water only?

Baxi combi 80Eco boiler heats radiators when selector switch is on both central heating and domestic hot water positions.
Boiler keeps running and can not be cut out by thermostat or timer settings. Is this a faulty selector switch?
Paul Hyatt, April 2008
Just a quick note to say thanks to every one took a chance on it being the dhw switch as it wasn`t clicking like the ch switch was , bought one off the shelf from a local heating spares supplier fitted it myself as was quite easy to do one for one wiring boilers working fine now once again thanks

buster, June 2012
I have the same problem the c h micro switch has got continunity across it when pushed in but the valve only returns when you turn off the power. guessing by what i read its the h w micro switch that needs replacing . what do you all think .
Please answer

buster, June 2012
It is the microswitch. Only problem is that the manual does not tell you what the part number is and there is another microswitch on the CH side. They often get confused when buying on the web.

John, February 2009
I have the same problem as this...

can anyone tell me if the diverter valve is stuck will it need replacing of can it be fixed.

Cheers

Pete H, August 2008
req new D.H.W flow switch fitted on front of diverter valve to the right hand side
George

George, April 2008
Your right Bob it was a stuck micro switch on the diverter valve. The switch was therefore calling for hot water without the taps being turned on.

Paul, April 2008
I had the same problem.
You need a new microswitch which costs around £25

Bob, April 2008
Sounds like a problem with a stuck / duff diverter valve, if it heats rad on dhw setting, it must be stuck in ch position

T, April 2008
link Click here to see other fixes for Baxi.