Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

What is the tap to repressurize the boiler?

I have a Baxi Duo condensing combination boiler and read the instruction on how to repressurize it but cannot find the tap... please help.
Sam
Sambo Seng, May 2008
Look underneath the boiler. There is usually a 'semi built' in filling loop. The 2 pipes to the right are joined together by a looped pipe with 2 valves on it. This pipe runs to roughly half way across the bottom and back. The logic is that if the valve is in line with the pipe it is ON and across is OFF. Open one valve and then when you open the second the pressure will increase. Shut the valves when you have reached 1 - 1.5 bar.
The fact that you have to do this could indicate a leak in your system or perhaps a pressure vessel fault.

PS It is possible that a conventional filling loop has been fitted but these generally come with the kit I have mentioned above

Slugbabydotcom, May 2008