andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    tom dimmock asked ... How can i mend the lid on russell hobbs elec?    |    Click here to ask your question

glow worm betacom 24?

the boiler lockout indicator is on, burner indicator is off, and it wont reset???
Phil Leeder, May 2008
Betacom 24 boiler, run off gas bottles. First bottle ran out. Switched bottles, but the boiler won't start. How do I reset it?

Tony, December 2020
power going in but green light is off ??

jhonny, January 2014
is it overheat or flame failure lockout?

chris, November 2009
if system pressure is below 1.5 bar boiler will trip out top up to 1.7 turn boiler power off and then on ,should be ok if not faulty high limit reset switch or pcb manchesterplumber/hotmail.co.uk

manchesterplumber, April 2009
high limit stat faulty, or pcb reset function faulty

T, May 2008
link Click here to see other fixes for Glow-worm Betacom 24.