start-up fault is detected under any of the following conditions of the
main thermistor (start-up detection fault):
after exceeding 40ºC, it fails to reach 60ºC within 10 sec.
after exceeding 60ºC, it fails to reach 80ºC within 10 sec.
after exceeding 80ºC, it fails to reach 100ºC within 10 sec.
after exceeding 100ºC, it fails to reach 120ºC within 10 sec.
after exceeding 120ºC, it fails to reach 140ºC within 10 sec.
after exceeding 140ºC, it fails to reach 160ºC within 10 sec.
after exceeding 160ºC, it fails to reach 180ºC within 10 sec.
after exceeding 180ºC, it fails to reach 195ºC within 10 sec.
Vale24, October 2008