GG asked ... Fix food processor motor?    |    T asked ... How do I turn the delay off on Electrolux DX302 dishwasher?    |    Helen asked ... How can I mend my Kenwood Gourmet FP505?    |    Roy Turner asked ... Kohlangaz Gosford HE fire?    |    Peter asked ... How can I mend a Powerwasher PRO PRO1800PWE?    |    Click here to ask your question

how to fix my medway boiler?

i have a medway boiler when i put the hot water tap on the pressure seems high and the gas flames are only half the size as normal and the water will not heat up
w. bailes, May 2008
they do have a water throttle on the side of the brass water section which can be adjusted to just slow the water and allow to heat. not the kind of thing that would fault though so cos of the half flame size problem i would say possibly more to do with the diaphragm maybe pin holed and allowing less differential pressure and not lifting gas valve open properly.

you can get a replacement diaphragm for the water section but get the o-rings too or you'll never stop the leak after you re-assemble it. trust me.

iain, May 2008