Terry nelson asked ... How to remove the flexible shaft from a curved shaft ryobi t?    |    Matt Longmore asked ... Non-start on Flymo XLT 250?    |    John asked ... How to fix my fireplace?    |    Ian Scott asked ... Remove cover off gas boiler?    |    wendy asked ... Old Creda Solar Plus Cooker will not come on?    |    Click here to ask your question

What is the problem with my Worcester Combi 350 boiler?

I have a Worcester 350 Combi boiler. During the last two to three weeks the pressure showing on my boiler pressure gauge has been climbing, if I drain out some of the water out of one of the radiators to reduce the pressure down to 1.5 bars, it will rise up again to 4 bars during the day ?? it does this twice or more every day.
Is the fault with a leaking filler tap ( there is a tap at the bottom that I have used in the past to fill up the radiators ) or is the problem elsewhere in the boiler, if so do you know what it is and the potential repair cost.
Geoff Wilson, June 2008
This problem is one of 2 possibilities, either the filler valve you use is passing water and will have to be replaced, or there is a leak between the system water and primary water in the dhw heat exchanger (not a huge job to change) not sure of the part costs in the uk.....

T, June 2008