Alan asked ... Problem with JCB 3CX transmission?    |    Lou asked ... Mac Allister 35cm electric lawn mower?    |    Ronald Charlwood asked ... Beko fridge/freezer not cold enough?    |    John Broadbent asked ... Advise?    |    suzy asked ... Brother kh-940 not in sync with DAK9 in interactive knitting?    |    Click here to ask your question

Intermittant hot water on Baxi 105e but heating OK?

Hi,

My Baxi 105e combi only gives hot water when I run the bath (and that's happening less and less - can't get any from kitchen/bathroom sink) or have the central heating on.

Thanks
Peter Eglintine, June 2008
quote T: (could be scaled up and require cleaning or need a new diaphram)

thats definately where i would start observing to see if the taps that do not work can make the microswitch. if not could be diaphragm, scaled up pin or blocked impulse tube

iain, June 2008
there is either a problem with the dhw flow sensor (could be scaled up and require cleaning or need a new diaphram) or the inline main water filter under the boiler could be partially blocked

T, June 2008