3 hours ago Karen asked ... Royal 480nt cash register?    |    andrew smith asked ... 2009 fiesta 1388 cc titainum?    |    Eric asked ... Strimmer fuel line?    |    Frank asked ... Working fine. No cold air?    |    c.m.brown asked ... Replace chuck on aeg power drill sb2e 700r?    |    Click here to ask your question

What is the problem when:-?

Vokera Compact combi(not condensing) is pressurising up to blow off constantly, although filler loop is disconnected
Shep, June 2008
they have a dual pass set up heat exchanger rather than a dhw plate so my guess would be heat exchanger shot.
hoses rot and leak on them too

iain, June 2008
the expansion vessel is either undercharged (needs to be charged to min 0.5 bar for 5m head) or else it has perished and will need replacing.

if charge is ok, and when air is released no water comes out, you may have another possible fault, that will require replacing the dhw heat exchanger (secondary water passing into primary water across the heat exchanger)

T, June 2008