Pam asked ... Do I need to open the housing to dry the motor?    |    James asked ... Remove enterprise enrolment from an Asus Chromebook C523N?    |    tom schwartz asked ... Bosch maxx 6?    |    Noman asked ... Reverse light switch?    |    Suzie asked ... Stuck Feed dog?    |    Click here to ask your question

whats wrong with my vokera compact 24?

WHEN I TURN ON THE HOT WATER TAP THE FAN GOES BUT THE BOILER DOES NOT FIRE UP THE MANUAL SAYS CHECK AND/OR REPLACE PCB. HOW DO YOU CHECK A PRINTED CIRCUIT BOARD?
CHRIS LOCKWOOD, July 2008
my money would be on a fan/flue related problem
not making the air pressure switch.
if the boiler fires with the combustion cover off,
have your engineer check the fan venturis.

jason, July 2008
could be a number of faults, from asp, to ignition, gas valve, gas pressure, pcb...etc...

no way to 'test' the pcb, ways to rule out all the other possibilities through 'fault logic' then replace pcb is they check out.....

you may change the pcb, suck it and see method!, or get a technician out to 'professionally' retify your problem as you are not permitted to tamper with any of the other possible issues

T, July 2008