Ben asked ... Toyota Yaris French or Japanese?    |    Andy asked ... How can I mend my MacAlistair 450w hedge trimmer?    |    Felix asked ... Hitachi vt-m70em?    |    Katie Bond asked ... Fixing auto threader on Baby Lock Enlighten Overlocker?    |    Chris. asked ... Miele W800 novotronic washing machine?    |    Click here to ask your question

how can i fix my ideal isar he24 condencing combi boiler?

the boiler fires up every 5 minutes to preheat the water in the domestic hot water heat exchanger.The manual says it occasionally comes on.Can I disable this.
Paul Goodwin, July 2008
no you can't disable it. if it comes on every 5 minutes you must have a leak on you hot water pipes or a dripping hot tap. Ideal do a kit to fit in place of the hot water thermistor, which is a flow switch, which will stop this pre-heat

Paul the gasman, July 2008
link Click here to see other fixes for Ideal Isar HE24.